beautypg.com

Set remote v35 cts, Set remote v35 data, Set remote v35 cts -124 – Carrier Access Access Navigator User Manual

Page 581: Set remote v35 data -124

background image

Access Navigator - Release 1.8

August 2003

18-125

CLI Language Reference

CLI Command List

Set Remote V35 CTS

Purpose:

Sets the Access Bank II V.35 interface Clear to Send (CTS) timing and signal levels for
flow control. The CTS logic signal can be always high or low, or set to follow the
Carrier Detect (CD) or Ready to Send (RTS) signals.

Security:

Level 2 (operator)

Syntax:

set remote <n> v35 cts <cd|high|low|rts>

Example:

set remote 9 v35 cts rts

Set Remote V35 Data

Purpose:

Sets the Access Bank II V.35 interface data polarity to normal or inverted.

Security:

Level 2 (operator)

Syntax:

set remote <n> v35 data <invert|normal>

Example:

set remote 9 v35 data normal

Field

Description

n

DS1 number, 1 to 32.

cd

CTS follows CD.

high

CTS always high.

low

CTS always low.

rts

CTS follows RTS.

Field

Description

n

DS1 number, 1 to 32.

invert

Invert data.

normal

No data inversion.