Table 14-7 on – Carrier Access Access Navigator User Manual
Page 333
![background image](/manuals/63313/333/background.png)
Access Navigator - Release 1.8
August 2003
14-13
Alarm Clearing
Clear Alarms – EOC
Table 14-7 EOC Warning Alarm Message and Trouble Clearing Procedure
Event Message
Description
Trouble Clearing Procedure
Alarm Count List
Change
Event Report Service Problem.
(Reported only if the alarm count
list has been created. The alarm
count list is created by DMS
switches.)
The number of alarms active in the
Access Navigator has changed.
Only those alarms reportable to
the switch and excluding Service
Problems are included in the alarm
count list.
The alarm is cleared after all
events reportable to the switch
have been cleared.
Analog Line
Termination Out of
Service
Event Report Service Problem.
A previously in-service DS0
configured as an analog line
termination has been disabled
(set ds0
error condition has been detected
and the DS1 is now out of service.
Correct the problem with the
incoming DS1 signal, or provision
the DS1 as out of service.
DS1 Out of Service
Event Report Service Problem
(Reported only if DS1 type =
SWITCH).
A previously in-service DS1 has
been disabled (set ds1
down
) or an error condition has
been detected and the DS1 is now
out of service.
Correct the problem with the
incoming DS1 signal, or provision
the DS1 as out of service.
System Alarm State
Change
Event Report Service Problem
(5ESS only).
The severity of the system alarm
state has changed. Only those
events reportable to the switch and
excluding Service Problems are
included in the system alarm state.
The alarm is cleared after all
events reportable to the switch
have been cleared.