beautypg.com

Carrier Access Access Navigator User Manual

Page 597

background image

Access Navigator - Release 1.8

August 2003

18-141

CLI Language Reference

CLI Command List

Message:

Settings for DS1 9:
Circuit ID: CA DS1# 9
Up/Down: DOWN
Framing: ESF
Line Coding: B8ZS
Type: DROP
Clock Source: NORMAL
Line Build Out: CSU ATTEN FOR -15dB
Loop Code Detection: ON
Loop Back: OFF
Line Termination ID: 0 (for switch DS1s only)
Remote Device MGMT: CA IP 192.168.201.1
PPHONE Call Connection: Enabled
FDL Type: None
Send Code: NONE
Performance Thresholds: 15 min. 1 hour 1 day
-------- ------- ------
unavailable seconds: 0 0 0
severely errored seconds: 0 0 0
errored seconds: 0 0 0
sev. errored frame seconds: 0 0 0
degraded minutes: 0 0 0
linecode violations: 0 0 0

NOTE:

The Performance Thresholds are threshold values, not error counts.

Description:

Item

Description

Circuit ID

Circuit identifier set by user for the DS1 number.

Up/Down

Link service status: UP, DOWN.

Framing

D4 (SF), ESF, SLC96 (S4).

Line Coding

AMI, B8ZS.

Type

DROP, GROOM, SWITCH. Switch type appears only with GR-
303 option.

Clock Source

NORMAL, LOOP.

Line Build Out

DSX-1 equalization (ft.), CSU attenuation (dB).

Loop Code Detection

ON, OFF.

Loop Back

OFF, LINE, PAYLOAD.

Line Termination ID

Line termination identifier, 1 to 28, set by user (used by GR-303
only.

Remote Device MGMT

NONE, CAFDL, CAIP , DS1 .