18-58

August 2003

Access Navigator - Release 1.8

CLI Language Reference

CLI Command List

Reset Remote

CAUTION!

T

HE

RESET

REMOTE

COMMAND

WILL

DISRUPT

T1

VOICE

AND

DATA

SERVICES

THROUGH

THE

REMOTE

A

CCESS

B

ANK

II

FOR

ABOUT

15

SECONDS

.

Purpose:

Resets a remote Access Bank II connected to the Access Navigator through a DS1. This
command resets and restores the Access Bank controllers, T1 connection, all
crossconnections, and all remote interfaces to the configuration settings stored in
nonvolatile memory.

The reset operation takes about 15 seconds, during which all T1 voice and data services
through the remote Access Bank II will be disrupted. Management communications
with the remote terminal will also be disabled for about 15 seconds (30 seconds for a
remote Access Bank II/SNMP).

Security:

Level 2 (operator)

Syntax:

reset remote

Example:

reset remote 9

Reset Standby

Purpose:

Produces a soft reset of the standby Controller card. The entire process takes about 30
seconds. You can use the status equipment command to verify operational status
of the standby Controller card.

Security:

Level 2 (operator)

Syntax:

reset standby

The reset standby command has the following effects:

l

Resets only the standby Controller card.

l

Does not disrupt service or active Controller operation.

l

Upon restart, the standby Controller receives the current database configuration
settings and status data from the active Controller.

Field

Description

n