beautypg.com

Reset all, Reset ds1 framer, Reset all -57 – Carrier Access Access Navigator User Manual

Page 513: Reset ds1 framer -57, Reset all on, Reset ds1 framer on, Eset, Reset all caution, Reset ds1 framer caution

background image

Access Navigator - Release 1.8

August 2003

18-57

CLI Language Reference

CLI Command List

Reset All

CAUTION!

T

HE

RESET

ALL

COMMAND

WILL

INTERRUPT

SERVICE

FOR

ABOUT

30

SECONDS

. DCS

CROSSCONNECTS

WILL

BE

RESTORED

. GR-303

CROSSCONNECTS

WILL

BE

LOST

.

Purpose:

Produces a soft reset of both Controller cards. It is equivalent to a hard reset, in which
the Access Navigator is powered off and on again. The entire process takes about 30
seconds.

Security:

Level 2 (operator)

Syntax:

reset all

The reset all command has the following effects:

l

Resets both Controller cards.

l

Erases all RAM data, including the GR-303 crossconnects, status, event log,
time, and date.

l

Does not affect provisioning and other settings stored in flash memory.

l

Upon restart, provisioning and other settings are restored.

l

Upon restart, the clock starts at time 00:00:00 and date 01/01/1998.

l

Upon restart, the status interval timer starts at zero seconds.

Reset DS1 Framer

CAUTION!

T

HE

RESET

DS1”

COMMAND

WILL

MOMENTARILY

DISRUPT

SERVICE

WHILE

THE

DS1

FRAMER

RESYNCHRONIZES

.

Purpose:

Enables the operator to reset one or more DS1 framers. The command resets the DS1
receiver and may be used to test Loss of Frame recovery.

Security:

Level 2 (operator)

Syntax:

reset ds1

Example:

reset ds1 9

Example:

reset ds1 5-8

Field

Description

n