Carrier Access Access Navigator User Manual
Page 294

12-16
August 2003
Access Navigator - Release 1.8
Provision Remote Adit 600 via FDL
Provision DS0 Crossconnects (if required)
NOTE:
To change existing DS0 connections, you must first disconnect them before
making new connections.
3. Disconnect existing DS0s with the following command:
disconnect
Example:
disconnect 10:16-24
4. Connect DS0s (see Figure 1) to make 2-way connections between DS0s, or fractional groups of
DS0s, with the following command:
connect
Example:
connect 10:16 18:21
Example:
connect 16:17-24 21:5-12
Figure 12-3. Crossconnect Examples
connect ds0 10:16 18:21
connect ds0 12:3 17:10
connect ds0 15:7 21:4
connect ds0 16:17-24 21:5-12
DS1 #10
DS1 #12
DS0 #16
DS0 #3
DS1 #15
DS0 #7
DS1 #16
DS0 #17-24
DS1 #21
DS0 #4
DS0 #5-12
DS1 #17
DS1 #18
DS0 #10
DS0 #21
Access Navigator
Command Examples: (A)
(B)
(C)
(D)
(A)
(B)
(C)
(D)