beautypg.com

Obtain provisioning information, Verify system equipment configuration, Obtain provisioning information -11 – Carrier Access Access Navigator User Manual

Page 259: Verify system equipment configuration -11, Caution

background image

Access Navigator - Release 1.8

August 2003

11-11

Provision Remote Access Bank II

Obtain Provisioning Information

Obtain Provisioning Information

1. Obtain office records for installation site.

2. Obtain circuit orders for remote Access Bank II service turn up.

Verify System Equipment Configuration

CAUTION!

V

ERIFY

CURRENT

CONFIGURATION

AND

SERVICE

STATUS

WITH

OFFICE

RECORDS

BEFORE

ADDING

,

DELETING

,

OR

CHANGING

CIRCUITS

.

NOTE:

The factory default sets all DS1s and DS0s in-service (up). To prevent

inadvertent service disruptions, it is good practice to set circuits out of service (down) when
not in use or not provisioned in the switch. Set the type of unused DS0 channels to match
the DS0 type configured on the device at the other end of the DS1. If the DS1 is not
terminated, set the type to voice.

1. Start management session (see Start Management Session on

page 7-1

).

2. Show system equipment configuration with the following command:

status equipment

A message similar to the following will appear, showing the equipment card slots, service status,
and Controller software version.

Equipment

Status

Version

---------

------

-------

Controller A

Active

01.70 GR-303 Option

Controller B

Standby

01.70 GR-303 Option

DS1 Card 1

Installed

1

DS1 Card 2

Installed

1

DS1 Card 3

Installed

1

DS1 Card 4

Installed

1

DS1 Card 5

Installed

1

DS1 Card 6

Installed

1

DS1 Card 7

Card not installed

DS1 Card 8

Card not installed

3. Verify number of DS1 circuits installed by comparing equipment status with office records. If there