Obtain provisioning information, Verify system equipment configuration, Obtain provisioning information -11 – Carrier Access Access Navigator User Manual
Page 259: Verify system equipment configuration -11, Caution

Access Navigator - Release 1.8
August 2003
11-11
Provision Remote Access Bank II
Obtain Provisioning Information
Obtain Provisioning Information
1. Obtain office records for installation site.
2. Obtain circuit orders for remote Access Bank II service turn up.
Verify System Equipment Configuration
CAUTION!
V
ERIFY
CURRENT
CONFIGURATION
AND
SERVICE
STATUS
WITH
OFFICE
RECORDS
BEFORE
ADDING
,
DELETING
,
OR
CHANGING
CIRCUITS
.
NOTE:
The factory default sets all DS1s and DS0s in-service (up). To prevent
inadvertent service disruptions, it is good practice to set circuits out of service (down) when
not in use or not provisioned in the switch. Set the type of unused DS0 channels to match
the DS0 type configured on the device at the other end of the DS1. If the DS1 is not
terminated, set the type to voice.
1. Start management session (see Start Management Session on
).
2. Show system equipment configuration with the following command:
status equipment
A message similar to the following will appear, showing the equipment card slots, service status,
and Controller software version.
Equipment
Status
Version
---------
------
-------
Controller A
Active
01.70 GR-303 Option
Controller B
Standby
01.70 GR-303 Option
DS1 Card 1
Installed
1
DS1 Card 2
Installed
1
DS1 Card 3
Installed
1
DS1 Card 4
Installed
1
DS1 Card 5
Installed
1
DS1 Card 6
Installed
1
DS1 Card 7
Card not installed
DS1 Card 8
Card not installed
3. Verify number of DS1 circuits installed by comparing equipment status with office records. If there
is a discrepancy, follow standard practices to resolve problem.