beautypg.com

Carrier Access Access Navigator User Manual

Page 543

background image

Access Navigator - Release 1.8

August 2003

18-87

CLI Language Reference

CLI Command List

remote

loopdown command.

NOTE:

Only one port of the Access Bank II can be looped up at a time. If a

loopup command is received for a second port, the first port will be looped down
automatically before the second port is looped up.

NOTE:

To check remote loopback status, use the read remote loopback

command. See Read Remote Loopback on

page 18-51

.

Purpose:

Sends an out-of-band (FDL) message to a remote Access Bank II over the Access
Navigator DS1. It is used to verify T1 signal processing in the Access Bank II. Payload
loopbacks can be used with unframed PRBS and QRSS test patterns (see Send DS1
Payload
on

page 18-75

and Send DS1 Payload Test on

page 18-77

).

When the operator enters a send remote command, the Access Navigator transmits
a message over the Carrier Access FDL management channel of the drop DS1. The
Access Navigator’s drop DS1 is the Access Bank’s T1 connection.

The send remote t1 tsi loopup command should cause the remote Access
Bank II to perform a Time Slot Interchange (TSI) loopback. This takes the received
DS0 data, loops it in the TSI, and sends it back to the T1 output (see Figure 18-17). To
loopdown the interface, use the send remote loopdown command.

Figure 18-17. Remote T1 TSI Loopup

Security:

Level 2 (operator)

Syntax:

send remote t1 tsi loopup

Example:

send remote 9 t1 tsi loopup

Message:

Loop command sent to remote.

Field

Description

n

DS1 number, 1 to 32

DS1

Access

Navigator

Framer

CA FDL

Command

Access Bank II

T1

TSI Loopup

T1

Time Slot

Interchange