beautypg.com

Carrier Access Access Navigator User Manual

Page 520

background image

18-64

August 2003

Access Navigator - Release 1.8

CLI Language Reference

CLI Command List

Purpose:

Sends an out-of-band (FDL) line loopup or loopdown code over the Access Navigator
DS1. It is used with other commands and test equipment to verify that the DS1 signal
is reaching far-end CSU equipment, such as the Access Bank.

Line loopups can be used with either unframed (line) or framed (payload) patterns and
test commands, including Send DS1 Line , Send DS1 Line Test,
Send DS1 Payload , and Send DS1 Payload Test.

When the operator sends a line loopup command, the Access Navigator transmits
a T1.403 defined out-of-band line loopback activate code over the FDL channel of the
drop DS1 to the CSU. After the required 5-second integration time, the CSU should
perform a line loopback, which loops the received DS1 frame back to the DS1 transmit
output (see Figure 18-4).

When testing is complete, send a line loopdown command.

NOTE:

This command will send one of the following T1.403 defined FDL

code words, repeated for 5 seconds.
Line loopback activate:

00001110 11111111

Line loopback deactivate:

00111000 11111111

Figure 18-4. Send DS1 Line Loopup

Security:

Level 2 (operator)

Syntax:

send ds1 line <loopup|loopdown>

Field

Description

n

DS1 number, 1 to 32, or a range of numbers such as 2-8.

loopup

Enable line loopback.

loopdown

Disable line loopback.

DS1

Line

Interface

Unit

Framer

Access Navigator

IN

OUT

Time Slot

Interchange

Code

Generator

CSU

Far End

Line Loopup

Line

Loopup

Command

FDL

Code

Access Bank II