Provision GR-303 Service

Turn Up Service

Turn Up Service

1. Show current DS1 status with the following command:

status ds1

Example:

status ds1 13

2. Show current DS0 status with the following command:

status ds0

Example:

status ds0 13:1-16

3. If drop DS1 and DS0 settings are correct, skip remaining steps.

4. Set DS1s and DS0s to in-service (up) status with the following commands:

set ds1 up
set ds0
up

Example:

set ds1 13 up

Example:

set ds0 13:1-16 up

Test Circuits

NOTE:

The Access Navigator supports the following T1.403 loop tests:

• Responds to ESF bit patterned loop requests (when loopdetect is on)
• Generates ESF bit patterned loop requests
• Generates SF CSU inband loopcodes

NOTE:

The Access Navigator provides line and payload loopback commands for

troubleshooting line problems. See Diagnostics & Troubleshooting on

page 15-1

.

1. Follow standard practices to test subscriber drop DS1 circuits.

2. Follow standard practices to test DS0 connections.