Configuration Example

Network requirements

z

The switch is in the time zone of GMT+ 08:00:00.

z

The time stamp format of output log information is date.

z

UTC time zone will be added to the output information of the information center.

Network diagram

Figure 1-4 Network diagram

Configuration procedure

# Name the local time zone z8 and configure it to be eight hours ahead of UTC time.

clock timezone z8 add 08:00:00

# Set the time stamp format of the log information to be output to the log host to date.

system-view

System View: return to User View with Ctrl+Z.

[Switch] info-center timestamp loghost date

# Configure to add UTC time to the output information of the information center.

[Switch] info-center timestamp utc