# Add the event entries numbered 1 and 2 to the event table, which will be triggered by the following

extended alarm.

[Sysname] rmon event 1 log

[Sysname] rmon event 2 trap 10.21.30.55

# Add an entry numbered 2 to the extended alarm table to allow the system to calculate the alarm

variables with the (.1.3.6.1.2.1.16.1.1.1.9.1+.1.3.6.1.2.1.16.1.1.1.10.1) formula to get the numbers of all

the oversize and undersize packets received by Ethernet 1/0/1 that are in correct data format and

sample it in every 10 seconds. When the change ratio between samples reaches the rising threshold of

50, event 1 is triggered; when the change ratio drops under the falling threshold, event 2 is triggered.

[Sysname] rmon prialarm 2 (.1.3.6.1.2.1.16.1.1.1.9.1+.1.3.6.1.2.1.16.1.1.1.10.1) test 10

changeratio rising_threshold 50 1 falling_threshold 5 2 entrytype forever owner user1

# Display the RMON extended alarm entry numbered 2.

[Sysname] display rmon prialarm 2

Prialarm table 2 owned by user1 is VALID.

Samples type : changeratio

Variable formula : (.1.3.6.1.2.1.16.1.1.1.9.1+.1.3.6.1.2.1.16.1.1.1.10.1)

Description : test

Sampling interval : 10(sec)

Rising threshold : 100(linked with event 1)

Falling threshold : 10(linked with event 2)

When startup enables : risingOrFallingAlarm

This entry will exist : forever.

Latest value : 0