Hwping configuration, Hwping server configuration – H3C Technologies H3C S3600 Series Switches User Manual

Page 1055

background image

1-4

Test parameter

Description

dns

This parameter is used to specify a DNS domain name in an HWPing
DNS test group.

dns-server

This parameter is used to set the DNS server IP address in an HWPing
DNS test group.

HTTP operation type
(http-operation)

This parameter is used to set the type of HTTP interaction operation
between HWPing client and HTTP server.

FTP operation type
(ftp-operation)

This parameter is used to set the type of FTP interaction operation
between HWPing client and FTP server.

FTP login username and
password (username
and password)

The two parameters are used to set the username and password to be
used for FTP operation.

File name for FTP
operation (filename)

Name of a file to be transferred between HWPing client and FTP server

Size of a file to be
uploaded in an FTP
test(filesize)

Size of a file to be uploaded in an FTP test

Number of jitter test
packets to be sent per
probe
(jitter-packetnum)

z

Jitter test is used to collect statistics about delay jitter in UDP packet
transmission

z

In a jitter probe, the HWPing client sends a series of packets to the
HWPing server at regular intervals (you can set the interval). Once
receiving such a packet, the HWPing server marks it with a
timestamp, and then sends it back to the HWPing client. Upon
receiving a packet returned, the HWPing client computes the delay
jitter time. The HWPing client collects delay jitter statistics on all the
packets returned in the test. So, the more packets a jitter probe
sends, the more accurate the jitter statistics is, but the longer time the
jitter test costs.

Interval to send jitter test
packets (jitter-interval)

Each jitter probe will send multiple UDP test packets at regular intervals
(you can set the interval). The smaller the interval is, the faster the test is.
But a too small interval may somewhat impact your network.

Enable the HWPing
client to send Trap
messages (send-trap)

z

An HWPing test will generate a Trap message no matter whether the
test successes or not. You can use the Trap switch to enable or
disable the output of trap messages.

z

You can set the number of consecutive failed HWPing tests before
Trap output. You can also set the number of consecutive failed
HWPing probes before Trap output.

HWPing Configuration

The TCP/UDP/jitter tests need the cooperation of HWPing client and HWPing server. Other types of

tests need to configure HWPing client and corresponding different servers.

You can enable both the HWPing client and HWPing server functions on the switch, that is, the switch

can serve as an HWPing client and server simultaneously.

HWPing Server Configuration

The following table describes the configuration on HWPing server, which is the same for HWPing test

types that need to configure HWPing server.

Follow these steps to perform HWPing server configurations: