beautypg.com

Enabling the system to test connected cable – H3C Technologies H3C S3600 Series Switches User Manual

Page 168

background image

1-8

z

You cannot use the speed, duplex, mdi and shutdown commands on the ports running loopback

test.

z

Some ports do not support loopback test, and corresponding prompts will be given when you

perform loopback test on them.

Enabling the System to Test Connected Cable

You can enable the system to test the cable connected to a specific port. The test result will be returned

in five seconds. The system can test these attributes of the cable: Receive and transmit directions (RX

and TX), short circuit/open circuit or not, the length of the faulty cable.

Follow these steps to enable the system to test connected cables:

To do...

Use the command...

Remarks

Enter system view

system-view

Enter Ethernet port view

interface interface-type
interface-number

Enable the system to test
connected cables

virtual-cable-test

Required

SFP ports do not support this function.

Configuring the Interval to Perform Statistical Analysis on Port Traffic

By performing the following configuration, you can set the interval to perform statistical analysis on the

traffic of a port.

When you use the display interface interface-type interface-number command to display the

information of a port, the system performs statistical analysis on the traffic flow passing through the port

during the specified interval and displays the average rates in the interval. For example, if you set this

interval to 100 seconds, the displayed information is as follows:

Last 100 seconds input: 0 packets/sec 0 bytes/sec

Last 100 seconds output: 0 packets/sec 0 bytes/sec

Follow these steps to set the interval to perform statistical analysis on port traffic:

To do...

Use the command...

Remarks

Enter system view

system-view

Enter Ethernet port view

interface interface-type
interface-number

Set the interval to perform
statistical analysis on port
traffic

flow-interval interval

Optional

By default, this interval is 300
seconds.

This manual is related to the following products: