H3C Technologies H3C S3600 Series Switches User Manual
Page 982
1-8
Follow these steps to configure synchronous information output:
To do…
Use the command…
Remarks
Enter system view
system-view
—
Enable synchronous
information output
info-center synchronous
Required
Disabled by default
z
If the system information is output before you input any information following the current command
line prompt, the system does not echo any command line prompt after the system information
output.
z
In the interaction mode, you are prompted for some information input. If the input is interrupted by
system output, no system prompt (except the Y/N string) will be echoed after the output, but your
input will be displayed in a new line.
Configuring to Display the Time Stamp with the UTC Time Zone
To add UTC time zone to the time stamp in the information center output information, you must:
z
Set the local time zone
z
Set the time stamp format in the output destination of the information center to date
z
Configure to add the UTC time zone to the output information
Follow these steps to configure to display time stamp with the UTC time zone:
To do…
Use the command…
Remarks
Set the time zone for the system
clock timezone zone-name
{ add | minus } time
Required
By default, UTC time zone is set
for the system.
Enter system view
system-view
—
Log host
direction
info-center timestamp
loghost date
Set the time stamp
format in the output
destination of the
information center
to date
Non log
host
direction
info-center timestamp { log
| trap | debugging } date
Required
Use either command
Set to display the UTC time zone
in the output information of the
information center
info-center timestamp utc
Required
By default, no UTC time zone is
displayed in the output
information
Setting to Output System Information to the Console
Setting to output system information to the console
Follow these steps to set to output system information to the console: