3-12
Figure 3-4 Diagram for establishing connection to a console port
z
Launch a terminal emulation utility (such as Terminal in Windows 3.X or HyperTerminal in
Windows 95/Windows 98/Windows NT/Windows 2000/Windows XP) on the PC terminal, with the
baud rate set to 9,600 bps, data bits set to 8, parity check set to none, and flow control set to none.
z
Turn on the switch and press Enter as prompted. The prompt (such as
in the following figure.
Figure 3-5 The terminal window
z
Perform the following operations in the terminal window to assign IP address 202.38.160.92/24 to
VLAN-interface 1 of the switch.
[Sysname] interface Vlan-interface 1
[Sysname-Vlan-interface1] ip address 202.38.160.92 255.255.255.0
2) Perform Telnet-related configuration on the switch. Refer to
Authentication Mode Being None
Telnet Configuration with Authentication Mode Being Password
,
Telnet Configuration with Authentication Mode Being Scheme
3) Connect your PC/terminal and the Switch to an Ethernet, as shown in
. Make sure the
port through which the switch is connected to the Ethernet belongs to VLAN 1 and the route