1-20

Level

Privilege

Description

1 Monitor

Involves commands for system maintenance and service fault diagnosis.
Commands at this level are not allowed to be saved after being
configured. After the device is restarted, the commands at this level will
be restored to the default settings.

Commands at this level include debugging, terminal, refresh, reset,
and send.

2 System

Provides service configuration commands, including routing and
commands at each level of the network for providing services.

By default, commands at this level include all configuration commands
except for those at manage level.

3 Manage

Involves commands that influence the basic operation of the system and
the system support modules for service support.

By default, commands at this level involve file system, FTP, TFTP,
Xmodem command download, user management, level setting, as well
as parameter setting within a system (the last case involves those
non-protocol or non RFC provisioned commands).

For how to configure the user privilege level, see Login Configuration.

Modifying the Command Level

All the commands are defaulted to different levels. The administrator can modify the default command

level to improve management flexibility.

Follow these steps to change the command level:

To do…

Use the command…

Remarks

Enter system view

system-view

Configure the command level in
a specified view

command-privilege level
level view view command

Required

Refer to

Table 1-7

for the

default settings.

z

You are recommended to use the default command level or modify the command level under the

guidance of professional staff; otherwise, the change of command level may bring inconvenience

to your maintenance and operation, or even potential security problem.

z

When you change the level of a command with multiple keywords or arguments, you should input

the keywords or arguments one by one in the order they appear in the command syntax. Otherwise,

your configuration will not take effect. The values of the arguments should be within the specified

ranges.

z

After you change the level of a command in a certain view to be lower than the default level, change

the level of the command used to enter the view accordingly.