Console port login configuration, Common configuration, Console port login – H3C Technologies H3C S3600 Series Switches User Manual
Page 46: Configuration
2-4
Console Port Login Configuration
Common Configuration
Table 2-2 Common configuration of console port login
Configuration
Remarks
Baud rate
Optional
The default baud rate is 9,600 bps.
Check mode
Optional
By default, the check mode of the console port is set to
“none”, which means no check bit.
Stop bits
Optional
The default stop bits of a console port is 1.
Console port
configuration
Data bits
Optional
The default data bits of a console port is 8.
AUX user interface
configuration
Configure the
command level
available to the
users logging in to
the AUX user
interface
Optional
By default, commands of level 3 are available to the
users logging in to the AUX user interface.
Make terminal
services available
Optional
By default, terminal services are available in all user
interfaces
Set the maximum
number of lines the
screen can contain
Optional
By default, the screen can contain up to 24 lines.
Set history
command buffer
size
Optional
By default, the history command buffer can contain up
to 10 commands.
Terminal
configuration
Set the timeout time
of a user interface
Optional
The default timeout time is 10 minutes.
The change to console port configuration takes effect immediately, so the connection may be
disconnected when you log in through a console port and then configure this console port. To configure
a console port, you are recommended to log in to the switch in other ways. To log in to a switch through
its console port after you modify the console port settings, you need to modify the corresponding
settings of the terminal emulation utility running on your PC accordingly in the dialog box shown in
.