Configuring gvrp port registration mode – H3C Technologies H3C S3600 Series Switches User Manual
Page 155
1-6
Table 1-2 Relations between the timers
Timer
Lower threshold
Upper threshold
Hold 10
centiseconds
This upper threshold is less than or equal
to one-half of the timeout time of the Join
timer. You can change the threshold by
changing the timeout time of the Join
timer.
Join
This lower threshold is greater than or
equal to twice the timeout time of the
Hold timer. You can change the
threshold by changing the timeout time
of the Hold timer.
This upper threshold is less than one-half
of the timeout time of the Leave timer.
You can change the threshold by
changing the timeout time of the Leave
timer.
Leave
This lower threshold is greater than
twice the timeout time of the Join timer.
You can change the threshold by
changing the timeout time of the Join
timer.
This upper threshold is less than the
timeout time of the LeaveAll timer. You
can change the threshold by changing
the timeout time of the LeaveAll timer.
LeaveAll
This lower threshold is greater than the
timeout time of the Leave timer. You
can change threshold by changing the
timeout time of the Leave timer.
32,765 centiseconds
The following are recommended GVRP timer settings:
z
GARP hold timer: 100 centiseconds (1 second)
z
GARP Join timer: 600 centiseconds (6 seconds)
z
GARP Leave timer: 3000 centiseconds (30 seconds)
z
GARP LeaveAll timer: 120000 centiseconds (2 minutes)
Configuring GVRP Port Registration Mode
Follow these steps to configure GVRP port registration mode:
To do ...
Use the command ...
Remarks
Enter system view
system-view
—
Enter Ethernet port view
interface interface-type
interface-number
—
Configure GVRP port
registration mode
gvrp registration { fixed |
forbidden | normal }
Optional
By default, GVRP port
registration mode is normal.