Snmp test, Network requirements, Network diagram – H3C Technologies H3C S3600 Series Switches User Manual
Page 1083: Configuration procedure
1-32
SNMP Test
Network requirements
Both the HWPing client and the SNMP Agent are H3C S3600 series Ethernet switches. Perform
HWPing SNMP tests between the two switches to test the time required from Switch A sends an SNMP
query message to Switch B (SNMP Agent) to it receives a response from Switch B.
Network diagram
Figure 1-7 Network diagram for the SNMP test
Configuration procedure
z
Configure SNMP Agent (Switch B):
# Start SNMP agent and set SNMP version to V2C, read-only community name to public, and
read-write community name to private.
[Sysname] snmp-agent
[Sysname] snmp-agent sys-info version v2c
[Sysname] snmp-agent community read public
[Sysname] snmp-agent community write private
z
The SNMP network management function must be enabled on SNMP agent before it can receive
response packets.
z
The SNMPv2c version is used as reference in this example. This configuration may differ if the
system uses any other version of SNMP. For details, see SNMP – RMON Operation Manual.
z
Configure HWPing Client (Switch A):
# Enable the HWPing client.
[Sysname] hwping-agent enable
# Create an HWPing test group, setting the administrator name to administrator and test tag to snmp.
[Sysname] hwping administrator snmp
# Configure the test type as snmp.
[Sysname-hwping-administrator-snmp] test-type snmpquery
# Configure the destination IP address as 10.2.2.2.
[Sysname-hwping-administrator-snmp] destination-ip 10.2.2.2