beautypg.com

H3C Technologies H3C S3600 Series Switches User Manual

Page 1070

background image

1-19

To do…

Use the command…

Remarks

Configure the number
of probes per test

count times

Optional

By default, one probe is made per test.

Configure the
maximum number of
history records that
can be saved

history-records
number

Optional

By default, the maximum number is 50.

Configure the data
packet size

datasize size

Optional

By default, the data packet size is 100 bytes.

Configure a stuffing
character string

datafill string

Optional

By default, the numbers between 0 and 255 are
stuffed into datagrams in a cyclically way.

Configure a test
description

description string

Optional

By default, no description information is
configured.

Enable history record

history-record enable

Optional

By default, history record is not enabled.

Configure the
retaining time of
history record

history keep-time
keep-time

Optional

By default, the retaining time of history record is
120 minutes.

Configure statistics
interval and the
maximum number of
retained statistics
information

statistics { interval
interval | max-group
number }

Optional

By default, statistics interval is 120 minutes and
up to two pieces of statistics information can be
retained.

Configure the
retaining time of
statistics information

statistics keep-time
keep-time

Optional

By default, the retaining time of statistics
information is 120 minutes.

Configure test start
time and lifetime

test-time begin
{ hh:mm :ss
[ yyyy/mm/dd ] | now }
lifetime lifetime

Optional

By default, no test start time and lifetime is
configured.

Enable routing table
bypass

sendpacket passroute

Optional

By default, routing table bypass is disabled.

Configure the TTL

ttl number

Optional

By default, TTL is 20.

The sendpacket passroute command voids the
ttl command.

Configure the
automatic test interval

frequency interval

Optional

By default, the automatic test interval is zero
seconds, indicating no automatic test will be
made.

Configure the probe
timeout time

timeout time

Optional

By default, a probe times out in three seconds.

Configure the service
type

tos value

Optional

By default, the service type is zero.

Start the test

test-enable

Required