beautypg.com

Assigning a unit name to a switch, Assigning an irf fabric name to a switch – H3C Technologies H3C S3600 Series Switches User Manual

Page 800

background image

1-11

z

If the modified unit ID does not exist in the IRF fabric, the system sets its priority to 5 and saves it in

the unit Flash memory.

z

If the modified unit ID is an existing one, the system prompts you to confirm if you really want to

change the unit ID. If you choose to change it, the existing unit ID is replaced and the priority is set

to 5. Then you can use the fabric save-unit-id command to save the modified unit ID into the unit

Flash memory and clear the information about the existing one.

z

If auto-numbering is selected, the system sets the unit priority to 10. You can use the fabric

save-unit-id command to save the modified unit ID into the unit Flash memory and clear the

information about the existing one.

Priority is the reference for FTM program to perform automatic numbering. The value of priority can be

5 or 10. Priority 5 means the switch adopts manual numbering, and priority 10 means the switch adopts

automatic numbering. Manual numbering has a higher priority than automatic numbering.

After the configuration of numbering, you can use the following command in the table to save the local

unit ID in the unit Flash memory. When you restart the switch, it can load the unit ID configuration

automatically.

Follow these steps to save the unit ID of each unit in the IRF fabric:

To do…

Use the command…

Remarks

Save the unit ID of each unit in
the IRF fabric

fabric save-unit-id

Optional

Assigning a Unit Name to a Switch

Follow these steps to assign a unit name to a switch:

To do…

Use the command…

Remarks

Enter system view

system-view

Assign a unit name to a switch

set unit unit-id name unit-name Required

Assigning an IRF Fabric Name to a Switch

Only the switches with the same IRF fabric name can form an IRF fabric.

Follow these steps to assign a fabric name to a switch:

To do…

Use the command…

Remarks

Enter system view

system-view

Assign a fabric name to the
switch

sysname sysname

Optional

By default, the IRF fabric name
is H3C.