1-13
To do…
Use the command…
Remarks
Enter system view
system-view
—
Enable the information
center
info-center enable
Optional
Enabled by default.
Enable system
information output to the
trap buffer
info-center trapbuffer [channel
{ channel-number | channel-name } |
size buffersize]*
Optional
By default, the switch uses
information channel 3 to output
trap information to the trap
buffer, which can holds up to
256 items by default.
Configure the output
rules of system
information
info-center source { modu-name |
default } channel { channel-number |
channel-name } [ { log | trap | debug }
{ level severity | state state } ]*
Optional
Refer to
default output rules of system
information.
Set the format of time
stamp in the output
information
info-center timestamp { log | trap |
debugging } { boot | date | none }
Optional
By default, the time stamp
format of the output trap
information is date.
Setting to Output System Information to the Log Buffer
Follow these steps to set to output system information to the log buffer:
To do…
Use the command…
Remarks
Enter system view
system-view
—
Enable the information
center
info-center enable
Optional
Enabled by default.
Enable information
output to the log buffer
info-center logbuffer [ channel
{ channel-number |
channel-name } | size buffersize ]*
Optional
By default, the switch uses
information channel 4 to output log
information to the log buffer, which
can holds up to 512 items by
default.
Configure the output
rules of system
information
info-center source { modu-name |
default } channel
{ channel-number |
channel-name } [ { log | trap |
debug } { level severity | state
state } ]*
Optional
Refer to
for the default
output rules of system information.
Set the format of time
stamp in the output
information
info-center timestamp { log | trap
| debugging } { boot | date |
none }
Optional
By default, the time stamp format
of the output log information is
date.
Setting to Output System Information to the SNMP NMS
Follow these steps to set to output system information to the SNMP NMS: