beautypg.com

Remote port mirroring configuration example, Network requirements – H3C Technologies H3C S3600 Series Switches User Manual

Page 786

background image

1-11

# Display configuration information about local mirroring group 1.

[Sysname] display mirroring-group 1

mirroring-group 1:

type: local

status: active

mirroring port:

Ethernet1/0/1 both

Ethernet1/0/2 both

monitor port: Ethernet1/0/3

After the configurations, you can monitor all packets received on and sent from the R&D department

and the marketing department on the data detection device.

Remote Port Mirroring Configuration Example

Network requirements

The departments of a company connect to each other through S3600-EI Ethernet switches:

z

Switch A, Switch B, and Switch C are S3600-EI series switches.

z

Department 1 is connected to Ethernet 1/0/1 of Switch A.

z

Department 2 is connected to Ethernet 1/0/2 of Switch A.

z

Ethernet 1/0/3 of Switch A connects to Ethernet 1/0/1 of Switch B.

z

Ethernet 1/0/2 of Switch B connects to Ethernet 1/0/1 of Switch C.

z

The data detection device is connected to Ethernet 1/0/2 of Switch C.

The administrator wants to monitor the packets sent from Department 1 and 2 through the data

detection device.

Use the remote port mirroring function to meet the requirement. Perform the following configurations:

z

Use Switch A as the source switch, Switch B as the intermediate switch, and Switch C as the

destination switch.

z

On Switch A, create a remote source mirroring group, configure VLAN 10 as the remote-probe

VLAN, ports Ethernet 1/0/1 and Ethernet 1/0/2 as the source ports, and port Ethernet 1/0/4 as the

reflector port.

z

On Switch B, configure VLAN 10 as the remote-probe VLAN.

z

Configure Ethernet 1/0/3 of Switch A, Ethernet 1/0/1 and Ethernet 1/0/2 of Switch B, and Ethernet

1/0/1 of Switch C as trunk ports, allowing packets of VLAN 10 to pass.

z

On Switch C, create a remote destination mirroring group, configure VLAN 10 as the remote-probe

VLAN, and configure Ethernet 1/0/2 connected with the data detection device as the destination

port.

This manual is related to the following products: