beautypg.com

Network diagram, Configuration procedure, Telnetting to a switch – H3C Technologies H3C S3600 Series Switches User Manual

Page 67: Telnetting to a switch from a terminal

background image

3-11

z

Set the service type of VTY users to Telnet and the command level to 2.

z

Configure to authenticate users logging in to VTY 0 in scheme mode.

z

Only Telnet protocol is supported in VTY 0.

z

The screen can contain up to 30 lines.

z

The history command buffer can store up to 20 commands.

z

The timeout time of VTY 0 is 6 minutes.

Network diagram

Figure 3-3 Network diagram for Telnet configuration (with the authentication mode being scheme)

Configuration procedure

# Enter system view.

system-view

# Create a local user named guest and enter local user view.

[Sysname] local-user guest

# Set the authentication password of the local user to 123456 (in plain text).

[Sysname-luser-guest] password simple 123456

# Set the service type to Telnet, Specify commands of level 2 are available to users logging in to VTY 0..

[Sysname-luser-guest] service-type telnet level 2

[Sysname-luser-guest] quit

# Enter VTY 0 user interface view.

[Sysname] user-interface vty 0

# Configure to authenticate users logging in to VTY 0 in the scheme mode.

[Sysname-ui-vty0] authentication-mode scheme

# Configure Telnet protocol is supported.

[Sysname-ui-vty0] protocol inbound telnet

# Set the maximum number of lines the screen can contain to 30.

[Sysname-ui-vty0] screen-length 30

# Set the maximum number of commands the history command buffer can store to 20.

[Sysname-ui-vty0] history-command max-size 20

# Set the timeout time to 6 minutes.

[Sysname-ui-vty0] idle-timeout 6

Telnetting to a Switch

Telnetting to a Switch from a Terminal

1) Assign an IP address to VLAN-interface 1 of the switch (VLAN 1 is the default VLAN of the switch).

z

Connect the serial port of your PC/terminal to the console port of the switch, as shown in

Figure 3-4