Chapter 47 lcd controller, Overview, Features – FUJITSU MB91460 SERIES FR60 User Manual
Page 937

921
Chapter 47 LCD Controller
1.Overview
Chapter 47 LCD Controller
1. Overview
LCD allows display of up to 160 cells and selection of a duty cycle from 1/2, 1/3 and 1/4.
LCD has many applications.
2. Features
• Quantity: 1 (4 common x 40 segment)
• Display: Up to 160 cells (for 1/4 duty cycle)
• Duty cycle: Selectable from options: 1/2, 1/3 and 1/4.
• Bias: Fixed at 1/3
• Frame period: Selectable from four options. (For clock, peripheral clock or subclock is selectable.)
• Driver: Built-in (for internal divided resistors), or external divided resistors can be connected to the V0 - V3
pins.
• Data memory: Built-in 20-byte data memory for display
• Stop mode: Enable LCD display in the sub-stop mode.
• Blank display: Selectable.
• Pin: The SEG0-39 of COM0-4 pin usage can be switched between general and specialized purposes.
• Other: External divided resistors can be also used to shut off the current when LCD is deactivated.
VRAM19
VRAM1
VRAM2
bit 0
Internal Divided Resistors
or
External Divided Resistors
Timing Circuit
Prescaler
Peripheral
clock
Sub-clock
AC Circuit
Common
Segment
Driver
Driver
bit 7
bit 6
bit 5
bit 4
bit 3
bit 2
bit 1