background image

796

Chapter 39 Programmable Pulse Generator

2.Features

• Interrupt: Choose from four choices:

• Software trigger

• Counter borrow (cycle match)

• Duty match

• Counter borrow (cycle match) or duty match

• Activation trigger:

• Software trigger

• Internal triggers

Reload timer output 0 (TOT0) available as trigger for PPG0-PPG3
Reload timer output 1 (TOT1) available as trigger for PPG0-PPG3
Reload timer output 2 (TOT2) available as trigger for PPG4-PPG7
Reload timer output 3 (TOT3) available as trigger for PPG4-PPG7
Reload timer output 4 (TOT4) available as trigger for PPG8-PPG11
Reload timer output 5 (TOT5) available as trigger for PPG8-PPG11
Reload timer output 6 (TOT6) available as trigger for PPG12-PPG15
Reload timer output 7 (TOT7) available as trigger for PPG12-PPG15

• External triggers

Port GP14_0 (ICU0, RLT0 ext-trig) available as trigger for PPG0-PPG3/PPG8-PP11
Port GP14_1 (ICU1, RLT1 ext-trig) available as trigger for PPG0-PPG3/PPG8-PP11
Port GP14_2 (ICU2, RLT2 ext-trig) available as trigger for PPG0-PPG3/PPG8-PP11
Port GP14_3 (ICU3, RLT3 ext-trig) available as trigger for PPG0-PPG3/PPG8-PP11
Port GP14_4 (ICU4, RLT4 ext-trig) available as trigger for PPG4-PPG7/PPG12-PP15
Port GP14_5 (ICU5, RLT5 ext-trig) available as trigger for PPG4-PPG7/PPG12-PP15
Port GP14_6 (ICU6, RLT6 ext-trig) available as trigger for PPG4-PPG7/PPG12-PP15
Port GP14_7 (ICU7, RLT7 ext-trig) available as trigger for PPG4-PPG7/PPG12-PP15