913

Chapter 45 D/A Converter

5.Operation

5. Operation

The operations of the D/A converter are described below.

(1)

Digital value setting (software-programmable)

(2)

D/A conversion in progress

(3)

Output enabled (software-programmable)

(4)

Analog value output

(5)

Digital value rewrite (software-programmable)

(6)

D/A conversion in progress

(7)

Output level finalized

(8)

Output disabled (software-programmable)

(9)

Fixed 0 V output

A0h

60h

(1)

(2)

(3)

(4)

(5)

(6)

(7)

(8)

(9)

DADR0/-
DADR1

DAE

DA0/DA1

output level

0A0h

060h