Chapter 37 Output Compare

6.Settings

6. Settings

*: For the setting procedure, refer to the section indicated by the number.

*: For the setting procedure, refer to the section indicated by the number.

*: For the setting procedure, refer to the section indicated by the number.

Table 6-1 Settings Necessary for Using Output Compare

Settings

Setting Register

Setting

Procedure*

Free-run timer setting

See “

Chapter 35 Free-Run Timer (Page No.733)

---

Compare value setting

Compare register (OCCP0 - OCCP7)

See 7.1

Compare mode setting

Output control register
(OCS01, OCS23, OCS45, OCS67)

See 7.2

Stop compare operation

See 7.3

Set initial level of compare pin output

See 7.4

Set OCU0-OCU7 pins to output

Port function register (PFR15.0 - PFR15.7)
Extra port function register (EPFR15.0 - EPFR15.7)

See 7.5

Clear free-run timer

Timer control register
(TCCS2, TCCS3, TCCS6, TCCS7)
See “

Chapter 35 Free-Run Timer (Page No.733)

See 7.6

Enable compare operation (activate)

Output control register
(OCS01, OCS23, OCS45, OCS67)

See 7.7

Table 6-2 Item Necessary to Clear the Free-run Timer upon Compare-match.

Setting

Setting Register

Setting

Procedure*

Select free-run timer clear mode

Timer control register

(TCCS2, TCCS3, TCCS6, TCCS7)

See “

Chapter 35 Free-Run Timer (Page No.733)

See 7.8

Table 6-3 Item Necessary for Performing Interrupts

Setting

Setting register

Setting

Procedure*

Output compare interrupt vector,
output compare interrupt level setting

See “

Chapter 24 Interrupt Control (Page No.311)

See 7.9

Output compare interrupt setting
Clear interrupt request
Enable interrupt request

Output control register
(OCS01, OCS23, OCS45, OCS67)

See 7.11