Chapter 39 Programmable Pulse Generator

7.Q & A

7. Q & A

7.1 How do I set (rewrite) a cycle and a duty?

Period and duty value settings

• Set each cycle value in PPG Period Setting Register PCSR.

• Set each duty value in PPG Duty Setting Register PDUT.

• The PPG Period Setting and the PPG Duty Setting registers each have a buffer to allow the user to ignore

the write timing.

• Equation

PCSR register value = {Cycle/Count clock} –1

PDUT register value = {“H” width (duty)

*

/Count clock} –1

*: Normal polarity (OSEL= 0)

• Allowed range

PCSR register value = PCSR register value - FFFFh (65535)

PDUT register value = 0 - PCSR register value

Note: Be sure to set a cycle following the setting of a cycle. (See “

8. Caution (Page No.821)

”.)

7.2 How do I enable or disable PPG operations?

Enabling the PPG operation

Use the PPG operation enable bit (PCN.CNTE).

Enable PPG operation before starting the PPG.

(See “

8. Caution (Page No.821)

”.)

7.3 How do I set the PPG operation mode (PWM operation/one-shot operation)?

Operation mode selection

Use the mode selection bit (PCN.MDSE).

(See “

8. Caution (Page No.821)

”.)

7.4 How do I get it restarted?

Enable restart.

A restart of a PPG can be enabled while the PPG is in operation.

Use the Enable Restart bit (PCN.RTRG) to set.

(See “

8. Caution (Page No.821)

”.)

Control

PPG Operation Enable Bit (CNTE)

To stop a PPG operation

Set “0”.

To enable a PPG operation

Set “1”.

Operation Mode

Mode Selection Bit (MDSE)

To implement a PWM operation

Set “0”.

To implement a one-shot operation

Set “1”.