Chapter 20 Software Watchdog Timer

8.Caution

8. Caution

• Although the watchdog interval time corresponds to the one twice as long as the watchdog 1-bit counter, the

watchdog timer clear operation only clears the 1-bit counter used for detecting the watchdog. As a result, the
time margin to clear the watchdog timer is different from the interval time.

Watchdog interval time selection

• The watchdog timer is started once data is written in the watchdog timer control register.

• The watchdog timer control register is also the reset cause register and the status (INIT, HSTB, WDOG,

ERST, SRST and LINIT) is set to “0” when it is read.

• The watchdog reset holds the oscillation stability wait time.

(Refer to “

Chapter 18 Timebase Counter (Page No.249)

”.)

• The watchdog reset from the main RUN or the sub-RUN where the main clock oscillation is in process

cannot have the oscillation stability wait time because the main clock is oscillating.

• Refer to “

Chapter 19 Timebase Timer (Page No.263)

for the method of clearing the timebase counter that is the

count source for the watchdog timer.

• Clearing the timebase counter causes the watchdog reset timing to be postponed once.

WT1-WT0

Time margin to clear the watchdog timer

Interval time during which the watchdog

reset is generated

00

Φ × 2

20

(Initial value)

Φ × 2

20

to

Φ × 2

21

01

Φ × 2

22

Φ × 2

22

to

Φ × 2

23

10

Φ × 2

24

Φ × 2

24

to

Φ × 2

25

11

Φ × 2

26

Φ × 2

26

to

Φ Ч 2

27