Setting – FUJITSU MB91460 SERIES FR60 User Manual
Page 803

787
Chapter 38 Reload Timer
6.Setting
6. Setting
*: For the setting procedure, refer to the section indicated by the number.
*: For the setting procedure, refer to the section indicated by the number.
Table 6-1 Settings Necessary for Moving the Reload Timer (Internal Clock Operation)
Setting
Setting Registers
Setting
Procedure*
Reload value settings
Reload (TMRLR0-TMRLR7)
See7.1
Count clock selection (internal clock selection)
Reload timer control status
(TMCSR0-TMCSR7)
See 7.2
Enable reload timer count operation
See 7.3
Mode selection (reload /one-shot)
See 7.4
Output reversal specification
See 7.5
Reload trigger selection (activation selection)
Soft trigger
External trigger
(Rising edge/falling edge/both edges)
See 7.6
TOT0 - TOT7 pin output
(Extra) port function register
(PFR15.0 - PFR15.7 and EPFR15.0 -
EPFR15.7)
See 7.8
Generate activation trigger
–
See 7.10
Soft trigger
-> Software trigger bit setting
Reload timer control status
(TMCSR0-TMCSR7)
External trigger
-> Input trigger to TIN pin
External input
Table 6-2 Settings Necessary for Moving the Reload Timer (External Event Operation)
Setting
Setting Registers
Setting
Procedure*
Reload value setting
Reload (TMRLR0-TMRLR7)
See 7.1
Count clock selection (external event clock selection)
Reload timer control status
(TMCSR0-TMCSR7)
See 7.2
Enable reload timer count operation
See 7.3
Mode selection (reload /one-shot)
See 7.4
Output reversal specification
See 7.5
External event clock active edge selection
(Rising edge/falling edge/both edges)
See 7.7
TOT0 - TOT7 pin output
(Extra) port function register
(PFR15.0 - PFR15.7 and EPFR15.0 -
EPFR15.7)
See 7.8
TIN0 - TIN7 pin external event input
Port function register (PFR14.0 -
PFR14.7)
See 7.9
Generate activation trigger
Soft trigger
-> Software trigger bit setting
Reload timer control status
(TMCSR0-TMCSR7)
See 7.10