beautypg.com

Setting – FUJITSU MB91460 SERIES FR60 User Manual

Page 803

background image

787

Chapter 38 Reload Timer

6.Setting

6. Setting

*: For the setting procedure, refer to the section indicated by the number.

*: For the setting procedure, refer to the section indicated by the number.

Table 6-1 Settings Necessary for Moving the Reload Timer (Internal Clock Operation)

Setting

Setting Registers

Setting

Procedure*

Reload value settings

Reload (TMRLR0-TMRLR7)

See7.1

Count clock selection (internal clock selection)

Reload timer control status
(TMCSR0-TMCSR7)

See 7.2

Enable reload timer count operation

See 7.3

Mode selection (reload /one-shot)

See 7.4

Output reversal specification

See 7.5

Reload trigger selection (activation selection)

Soft trigger
External trigger

(Rising edge/falling edge/both edges)

See 7.6

TOT0 - TOT7 pin output

(Extra) port function register
(PFR15.0 - PFR15.7 and EPFR15.0 -
EPFR15.7)

See 7.8

Generate activation trigger

See 7.10

Soft trigger
-> Software trigger bit setting

Reload timer control status
(TMCSR0-TMCSR7)

External trigger
-> Input trigger to TIN pin

External input

Table 6-2 Settings Necessary for Moving the Reload Timer (External Event Operation)

Setting

Setting Registers

Setting

Procedure*

Reload value setting

Reload (TMRLR0-TMRLR7)

See 7.1

Count clock selection (external event clock selection)

Reload timer control status
(TMCSR0-TMCSR7)

See 7.2

Enable reload timer count operation

See 7.3

Mode selection (reload /one-shot)

See 7.4

Output reversal specification

See 7.5

External event clock active edge selection

(Rising edge/falling edge/both edges)

See 7.7

TOT0 - TOT7 pin output

(Extra) port function register
(PFR15.0 - PFR15.7 and EPFR15.0 -
EPFR15.7)

See 7.8

TIN0 - TIN7 pin external event input

Port function register (PFR14.0 -
PFR14.7)

See 7.9

Generate activation trigger

Soft trigger

-> Software trigger bit setting

Reload timer control status
(TMCSR0-TMCSR7)

See 7.10