beautypg.com

Sci data word formats (ssftd = 0), 2 -11, Figure 8-2. sci data word formats (ssftd = 0), 2 – Motorola DSP56301 User Manual

Page 247

background image

SCI Programming Model

Serial Communication Interface (SCI)

8

-11

Figure 8-2. SCI Data Word Formats (SSFTD = 0), 2

Mode 0

8-bit Synchronous Data (Shift Register Mode)

TX

(SSFTD = 0)

One Byte From Shift Register

Mode 2

10-bit Asynchronous (1 Start, 8 Data, 1 Stop)

TX

(SSFTD = 0)

D7 or

Data

Type

Stop

Bit

Mode 4

11-bit Asynchronous (1 Start, 8 Data, 1 Even Parity, 1 Stop)

TX

(SSFTD = 0)

D7 or

Data

Type

Stop

Bit

Even

Parity

Mode 5

11-bit Asynchronous (1 Start, 8 Data, 1 Odd Parity, 1 Stop)

TX

(SSFTD = 0)

Start

Bit

D7 or

Data

Type

Stop

Bit

Odd

Parity

Mode 6

11-bit Asynchronous Multidrop (1 Start, 8 Data, 1 Data Type, 1 Stop)

TX

(SSFTD = 0)

Start

Bit

Stop

Bit

Data

Type

Note: 1. Modes 1, 3, and 7 are reserved.

2. D0 = LSB; D7 = MSB.
3. Data is transmitted and received LSB first if SSFTD = 0,

or MSB first if SSFTD = 1.

D0

D1

D2

D3

D4

D5

D6

D7

0

1

0

D0

D1

D2

D3

D4

D5

D6

WDS2 WDS1 WDS0

0

0

0

1

0

0

D0

D1

D2

D3

D4

D5

D6

D0

D1

D2

D3

D4

D5

D6

Start

Bit

WDS2 WDS1 WDS0

Start

Bit

WDS2 WDS1 WDS0

1

0

1

WDS2 WDS1 WDS0

D0

D1

D2

D3

D4

D5

D6

D7

1

1

0

WDS2 WDS1 WDS0

0 = Data Byte

Data Type: 1 = Address Byte