background image

SCI Programming Model

8

-10

DSP56301 User’s Manual

Figure 8-1. SCI Data Word Formats (SSFTD = 1), 1

Mode 0

8-bit Synchronous Data (Shift Register Mode)

TX

(SSFTD = 1)

One Byte From Shift Register

Mode 2

10-bit Asynchronous (1 Start, 8 Data, 1 Stop)

TX

(SSFTD = 1)

Start

Bit

Stop

Bit

Mode 4

11-bit Asynchronous (1 Start, 8 Data, 1 Even Parity, 1 Stop)

TX

(SSFTD = 1)

Start

Bit

Stop

Bit

Even

Parity

Mode 5

11-bit Asynchronous (1 Start, 8 Data, 1 Odd Parity, 1 Stop)

TX

(SSFTD = 1)

Start

Bit

D0 or

Data

Type

Stop

Bit

Odd

Parity

Mode 6

11-bit Asynchronous Multidrop (1 Start, 8 Data, 1 Data Type, 1 Stop)

TX

(SSFTD = 1)

Start

Bit

Stop

Bit

Data

Type

D7

D6

D5

D4

D3

D2

D1

D0

WDS2 WDS1 WDS0

0

0

0

Note: 1.Modes 1, 3, and 7 are reserved.

2. D0 = LSB; D7 = MSB
3. Data is transmitted and received LSB first if SSFTD = 0, or MSB first if

SSFTD = 1

0 = Data Byte

Data Type: 1 = Address Byte

D0 or

Data

Type

D7

D6

D5

D4

D3

D2

D1

D7

D6

D5

D4

D3

D2

D1

D0 or

Data

Type

D7

D6

D5

D4

D3

D2

D1

D7

D6

D5

D4

D3

D2

D1

D0

WDS2 WDS1 WDS0

0

1

0

WDS2 WDS1 WDS0

1

0

0

WDS2 WDS1 WDS0

1

0

1

WDS2 WDS1 WDS0

1

1

0