Using /clt signal – Yaskawa Large Capacity Sigma II Series User Manual
Page 86

4 Parameter Settings and Functions
4.1.3 Limiting Torques
4-10
Using /CLT Signal
The following section describes the use of the contact output signal /CLT as a torque limit
output signal.
This signal indicates whether servomotor output torque (current) is being limited.
Settings: Pn402 (Forward Torque Limit)
Pn403 (Reverse Torque Limit)
Pn404 (Forward External Torque Limit): /P-CL input only
Pn405 (Reverse External Torque Limit): /N-CL input only
When the /CLT signal is used, the following parameter must be used to select the output sig-
nal.
Output
→ /CLT CN1-*1
Torque Limit Output
Speed/Torque
Control,
Position Control
ON Status
The circuit between CN1-
*1 and *2 is closed.
CN1-*1 is at low level.
Servomotor output torque is being limited.
(Internal torque reference is greater than the limit set-
ting.)
OFF Status
The circuit between CN1-
*1 and *2 is opened.
CN1-*1 is at high level.
Servomotor output torque is not being limited.
(Internal torque reference is less than the limit setting.)
Pn50F
Output Signal Selections 2
Factory
Setting:
0000
Speed/Torque
Control,
Position Control
+24 V
I/O power supply
Photocoupler output
Maximum operating voltage
per output: 30 VDC
Maximum operating current
per output: 50 mA DC
SERVOPACK
CN1-*1
CLT+
T-
CL
CN1-*2
Output terminal
CN1-25,26 (SO1)
CN1-27,28 (SO2)
CN1-29,30 (SO3)
/CLT
Torque limit
detection
2
3
1
Pn50F.0