8.2 Troubleshooting

This section describes causes and remedies for problems which cause an alarm display and for
problems which result in no alarm display.

8.2.1 Troubleshooting Problems with Alarm Displays

Problems that occur in the Servodrives are displayed on the panel operator as “A. ††” or
“CPF††”.“A.- -”, however, does not indicate an alarm. Refer to the following sections to
identify the cause of an alarm and the action to be taken.

Contact your Yaskawa representative if the problem cannot be solved by the described pro-
cedures.

„

A.02

A.02: Parameters Breakdown

Display and Outputs

Note: OFF: Output transistor is OFF (alarm state).

Status and Remedy for Alarm

Alarm Outputs

Alarm Code Outputs

ALM Output

ALO1

ALO2

ALO3

OFF

OFF

OFF

OFF

Cause

Remedy

A

Power turned OFF during parameter write.
Alarm occurred at next power ON.

• Initialize parameters using Fn005 and

reinput user settings.

• Replace SERVOPACK.

B

Circuit board (1PWB) defective.

Replace SERVOPACK.

At power ON

A, B