4.1 Settings According to Device Characteristics

4-5

4

4.1.2 Setting the Overtravel Limit Function

The overtravel limit function forces movable equipment parts to stop if they exceed the
allowable range of motion.

„

Using the Overtravel Function

To use the overtravel function, connect the overtravel limit switch input signal terminals
shown below to the correct pins of the SERVOPACK CN1 connector.

Connect limit switches as shown below to prevent damage to the devices during linear
motion.

Drive status with an input signal ON or OFF is shown in the following table.

→ Input P-OT CN1-42

Forward Run Prohibited
(Forward Overtravel)

Speed/Torque
Control,
Position Control

→ Input N-OT CN1-43

Reverse Run Prohibited
( Reverse Overtravel)

Speed/Torque
Control,
Position Control

P-OT

CN1-42 at low level
when ON

Forward rotation allowed. Normal operation status.

CN1-42 at high level
when OFF

Forward run prohibited (reverse rotation allowed).

N-OT

CN1-43 at low level
when ON

Reverse rotation allowed. Normal operation status.

CN1-43 at high level
when OFF

Reverse run prohibited (forward rotation allowed).

Forward rotation end

Reverse rotation end

Limit
switch

Servomotor

SERVOPACK

CN1-42

CN1-43

N-OT

P-OT

Limit
switch