A.03

A.03: Main Circuit Detector Error

Display and Outputs

Note: OFF: Output transistor is OFF (alarm state).

Status and Remedy for Alarm

„

A.04

A.04: Parameter Setting Error

Display and Outputs

Note: OFF: Output transistor is OFF (alarm state).

Status and Remedy for Alarm

Alarm Outputs

Alarm Code Outputs

ALM Output

ALO1

ALO2

ALO3

OFF

OFF

OFF

OFF

Cause

Remedy

A

Circuit board (1PWB or 2PWB) defective.

Replace SERVOPACK.

Alarm Outputs

Alarm Code Outputs

ALM Output

ALO1

ALO2

ALO3

OFF

OFF

OFF

OFF

Cause

Remedy

A

An out-of-range parameter was previously
set or loaded.

• Reset all parameters in range.
• Otherwise, re-load correct parameter.

B

Circuit board (1PWB) defective.

Replace SERVOPACK.

At power ON

A

At power ON

A, B