Appendix A List of Parameters
A-4
* 1. The multiturn limit value must be changed only for special applications. Changing it inappro-
priately or unintentionally can be dangerous.
Torque Related
Constants
Pn400
Torque Reference Input Gain
0.1 V/rated
torque
10 to 100
30
4.2.7
Pn401
Torque Reference Filter Time Constant
0.01 ms
0 to 65535
100
5.1.5
Pn402
Forward Torque Limit
%
0 to 800
800
4.1.3
Pn403
Reverse Torque Limit
%
0 to 800
800
4.1.3
Pn404
Forward External Torque Limit
%
0 to 800
100
4.1.3
Pn405
Reverse External Torque Limit
%
0 to 800
100
4.1.3
Pn406
Emergency Stop Torque
%
0 to 800
800
4.1.2
Pn407
Speed Limit during Torque Control
min
-1
0 to 10000
10000
4.2.7
Pn408
Torque Function Switches
-
-
0000
5.1.6
Pn409
Notch Filter Frequency
Hz
50 to 2000
2000
5.1.6
Sequence
Related
Constants
Pn500
Positioning Completed Width
reference
units
0 to 250
7
4.5.3
Pn501
Zero Clamp Level
min
-1
0 to 10000
10
4.4.3
Pn502
Rotation Detection Level
min
-1
1 to 10000
20
4.5.5
Pn503
Speed Coincidence Signal Output Width
min
-1
0 to 100
10
4.5.4
Pn504
NEAR Signal Width
reference
units
1 to 250
7
4.5.8
Pn505
Overflow Level
256
reference
units
1 to 32767
1024
5.2.1
Pn506
Brake Reference Servo OFF Delay Time
10 ms
0 to 50
0
4.4.4
Pn507
Brake Reference Output Speed Level
min
-1
0 to 10000
100
4.4.4
Pn508
Timing for Brake Reference Output dur-
ing Motor Operation
10 ms
10 to 100
50
4.4.4
Pn509
Momentary Hold Time
ms
20 to 1000
20
4.5.9
Pn50A
Input Signal Selections 1
∗3
-
-
2100
4.3.3
Pn50B
Input Signal Selections 2
∗3
-
-
6543
4.3.3
Pn50C
Input Signal Selections 3
∗3
-
-
8888
4.3.3
Pn50D
Input Signal Selections 4
∗3
-
-
8888
4.3.3
Pn50E
Output Signal Selections 1
∗3
-
-
3211
4.3.4
Pn50F
Output Signal Selections 2
∗3
-
-
0000
4.3.4
Pn510
Output Signal Selections 3
∗3
-
-
0000
4.3.4
Pn511
Fixed Parameter (Do not change.)
-
-
8888
-
Pn512
Output Signal Reversal Settings
∗3
-
-
0000
4.3.4
Other
Constants
Pn600
Regenerative Resistor Capacity
∗4
10 W
0 to capac-
ity
∗5
0
4.6
Pn601
Fixed Parameter (Do not change.)
-
0 to capac-
ity
∗5
0
-
Table A.1 List of Parameters (cont’d)
Category
Parameter
No.
Name
Unit
Setting
Range
Factory
Setting
Reference