6 Using the Digital Operator

6.2.11 Adjusting the Motor Current Detection Offset

6-50

Using the Panel Operator

1. Press the MODE/SET Key to select the auxiliary function mode.

2. Press the Up or Down Cursor Key to select the parameter Fn00E.

3. Press the DATA/SHIFT Key for a minimum of one second. The following display will

appear.

4. Press the MODE/SET Key. The display will change as shown below and offset will be

automatically adjusted.

5. Press the DATA/SHIFT Key for a minimum of one second to return to the auxiliary

function mode display.

This completes the automatic adjustment of the motor current detection offset.

MODE/SET

DATE/

Flashing for
one second