4 extending encoder cables – Yaskawa Large Capacity Sigma II Series User Manual
Page 182

4 Parameter Settings and Functions
4.8.4 Extending Encoder Cables
4-106
4.8.4 Extending Encoder Cables
Standard encoder cables have a maximum length of 20 m. If a longer cable is required, pre-
pare an extension cable as described below. The maximum allowable cable length is 50 m.
For 50-m encoder cables, only the cable lines and connectors are available. The cable must
be prepared by the user.
For more details, refer to 7.5.7 Encoder Cables.
Preparing 50-m (1968.50 in) Encoder Cables
• Cable Lines
When specifying the cable length, just specify the model number:
JZSP-CMP19-
The in the model number designates the length of the cable (in meters).
For example, to order 35-m cable, specify JZSP-CMP19-35 as the model number.
• Connectors or Connector Kits
Length
Cable Line Model Numbers
30 m (1181.10 in)
JZSP-CMP19-30
40 m (1574.80 in)
JZSP-CMP19-40
50 m (1968.50 in)
JZSP-CMP19-50
Type
Model
SERVOPACK end
Encoder connector (CN2)
socket
JZSP-CMP9-1
Servomotor end
Encoder connector plug and
cable clamp for SGMBH
servomotors
Plug
L: MS3108B20-29S
Straight: MS3106B20-29S
Cable clamp: MS3057-12A
EXAMPLE
- Tag Generator (30 pages)
- MP3300iec (82 pages)
- 1000 Hz High Frequency (18 pages)
- 1000 Series (7 pages)
- PS-A10LB (39 pages)
- iQpump Micro User Manual (300 pages)
- 1000 Series Drive Option - Digital Input (30 pages)
- 1000 Series Drive Option - CANopen (39 pages)
- 1000 Series Drive Option - Analog Monitor (27 pages)
- 1000 Series Drive Option - CANopen Technical Manual (37 pages)
- 1000 Series Drive Option - CC-Link (38 pages)
- 1000 Series Drive Option - CC-Link Technical Manual (36 pages)
- 1000 Series Drive Option - DeviceNet (37 pages)
- 1000 Series Drive Option - DeviceNet Technical Manual (81 pages)
- 1000 Series Drive Option - MECHATROLINK-II (32 pages)
- 1000 Series Drive Option - Digital Output (31 pages)
- 1000 Series Drive Option - MECHATROLINK-II Technical Manual (41 pages)
- 1000 Series Drive Option - Profibus-DP (35 pages)
- AC Drive 1000-Series Option PG-RT3 Motor (36 pages)
- Z1000U HVAC MATRIX Drive Quick Start (378 pages)
- 1000 Series Operator Mounting Kit NEMA Type 4X (20 pages)
- 1000 Series Drive Option - Profibus-DP Technical Manual (44 pages)
- CopyUnitManager (38 pages)
- 1000 Series Option - JVOP-182 Remote LED (58 pages)
- 1000 Series Option - PG-X3 Line Driver (31 pages)
- SI-EN3 Technical Manual (68 pages)
- JVOP-181 USB Copy Unit (2 pages)
- JVOP-181 (22 pages)
- SI-EN3 (54 pages)
- MECHATROLINK-III (35 pages)
- SI-ET3 (49 pages)
- EtherNet/IP (50 pages)
- SI-EM3 (51 pages)
- 1000-Series Option PG-E3 Motor Encoder Feedback (33 pages)
- 1000-Series Option SI-EP3 PROFINET (56 pages)
- PROFINET (62 pages)
- AC Drive 1000-Series Option PG-RT3 Motor (45 pages)
- SI-EP3 PROFINET Technical Manual (53 pages)
- A1000 Drive Option - BACnet MS/TP (48 pages)
- 120 Series I/O Modules (308 pages)
- A1000 12-Pulse (92 pages)
- A1000 Drive Software Technical Manual (16 pages)
- A1000 Quick Start (2 pages)
- JUNMA Series AC SERVOMOTOR (1 page)
- A1000 Option DI-101 120 Vac Digital Input Option (24 pages)