beautypg.com

Setup using the built-in panel operator – Yaskawa Large Capacity Sigma II Series User Manual

Page 164

background image

4 Parameter Settings and Functions

4.7.4 Absolute Encoder Setup

4-88

4. Pressing the Up Cursor Key will change the display as shown below. Continue pressing

the Up Cursor Key until “PGCL5” is displayed. If an erroneous key entry is made,
“nO_OP” will flash for one second and the display will return to the auxiliary function
mode. In that case, go back to step 3 above and perform the operation again.

5. When “PGCL5” is displayed, press the DSPL/SET Key. The display will change as fol-

lows, and the absolute encoder’s multiturn data will be cleared.

6. Press the DATA/ENTER Key to return the auxiliary function mode.

This completes the absolute encoder’s setup operation. Turn the power OFF and then back
ON again.

„

Setup Using the Built-in Panel Operator

1. Press the MODE/SET Key to select the auxiliary function mode.

2. Press the Up or Down Cursor Key to select the parameter Fn008.

3. Press the DATA/SHIFT Key for at least one second. The following display will appear.

4. Pressing the Up Cursor Key will change the display as shown below. Continue pressing

the Up Cursor Key until “PGCL5” is displayed. If an erroneous key entry is made,
“nO_OP” will flash for one second and the display will return to the auxiliary function
mode. In that case, go back to step 3 above and perform the operation again.

Up Cursor Key

When a Mistaken Key Entry is Made

Flashes for one second.

Returns to auxiliary function mode.

Up Cursor Key

Flashes for
1 second.