8 Inspection, Maintenance, and Troubleshooting

8.2.1 Troubleshooting Problems with Alarm Displays

8-10

„

A.32

A.32: Regenerative Overload

Display and Outputs

Note: OFF:Output transistor is OFF (alarm state). ON: Output transistor is

ON.

Status and Remedy for Alarm

Alarm Outputs

Alarm Code Outputs

ALM Output

ALO1

ALO2

ALO3

ON

ON

OFF

OFF

Cause

Remedy

A

Regenerative power exceeds the allowable
value.

Use an external regenerative resistor that
matches the regenerative power capacity.

B

Alarm occurs although an external regener-
ative resistor is used and the temperature
rise of the regenerative resistor is small.

Correct parameter Pn600.

During servomotor
operation

A, B