Sequence i/o signal monitor display, Input signal monitor display – Yaskawa Large Capacity Sigma II Series User Manual
Page 237

6.1 Basic Operation
6-17
6
Sequence I/O Signal Monitor Display
The following section describes the monitor display for sequence I/O signals.
Input Signal Monitor Display
Note: Refer to 4.3.3 Input Circuit Signal Allocation for details on input ter-
minals.
Input signals are allocated as shown above and displayed on the panel display of the SER-
VOPACK or the Digital Operator. They are indicated by ON/OFF display of seven-segment
LEDs in top and bottom rows. These segments turn ON depending on the input signals (ON
for “L” level and OFF for “H” level).
• When /S-ON signal is ON (Servo ON at “L” signal)
• When /S-ON signal is OFF
• When P-OT signal operates (Operates at “H” signal)
LED Number
Input Terminal Name
Factory Setting
1
SI0 (CN1-40)
/S-ON
2
SI1 (CN1-41)
/P-CON
3
SI2 (CN1-42)
P-OT
4
SI3 (CN1-43)
N-OT
5
SI4 (CN1-44)
/ALM -RST
6
SI5 (CN1-45)
/P-CL
7
SI6 (CN1-46)
/N-CL
8
(CN1-4)
SEN
7 6 5 4 3 2 1
Top: OFF ("H" level)
Bottom: ON ("L" level)
Number
8
EXAMPLE
The bottom segment
of number 1 is lit.
7 6 5 4 3 2 1
8
7 6 5 4 3 2 1
8
The top segment
of number 1 is lit.
7 6 5 4 3 2 1
8
The top segment