6.1 Basic Operation

6-17

6

„

Sequence I/O Signal Monitor Display

The following section describes the monitor display for sequence I/O signals.

Input Signal Monitor Display

Note: Refer to 4.3.3 Input Circuit Signal Allocation for details on input ter-

minals.

Input signals are allocated as shown above and displayed on the panel display of the SER-
VOPACK or the Digital Operator. They are indicated by ON/OFF display of seven-segment
LEDs in top and bottom rows. These segments turn ON depending on the input signals (ON
for “L” level and OFF for “H” level).

• When /S-ON signal is ON (Servo ON at “L” signal)

• When /S-ON signal is OFF

• When P-OT signal operates (Operates at “H” signal)

LED Number

Input Terminal Name

Factory Setting

1

SI0 (CN1-40)

/S-ON

2

SI1 (CN1-41)

/P-CON

3

SI2 (CN1-42)

P-OT

4

SI3 (CN1-43)

N-OT

5

SI4 (CN1-44)

/ALM -RST

6

SI5 (CN1-45)

/P-CL

7

SI6 (CN1-46)

/N-CL

8

(CN1-4)

SEN

7 6 5 4 3 2 1

Top: OFF ("H" level)
Bottom: ON ("L" level)

Number

8

EXAMPLE

The bottom segment
of number 1 is lit.

7 6 5 4 3 2 1

8

7 6 5 4 3 2 1

8

The top segment
of number 1 is lit.

7 6 5 4 3 2 1

8

The top segment
of number 3 is lit.