4.7 Absolute Encoders

4-97

4

„

Changing the Setting with the Hand-held Digital Operator

1. Press the DSPL/SET Key to select the auxiliary function mode.

2. Select the parameter Fn013. Press the Left or Right Cursor Key to select the digit. Press

the Up or Down Cursor Key to change the number.

3. Press the DATA/ENTER Key. The following display will appear.

4. Press the DSPL/SET Key. The following display will appear and the multiturn limit set-

ting in the absolute encoder will be changed.

5. Press the DATA/ENTER Key to return the auxiliary function mode.

This completes the procedure to change the multiturn limit setting in the absolute encoder.
Turn the power OFF and then back ON again.

„

Changing the Setting with the Built-in Panel Operator

1. Press the MODE/SET Key to select the auxiliary function mode.

2. Press the Up or Down Cursor Key to select the parameter Fn013.

Flashes for