7.5 Specifications and Dimensional Drawings for Peripheral Devices

7-55

7

• SGDH-3GDE, 4EDE, 5EDE SERVOPACKs

Connect a dynamic brake contactor and Surge Absorption Unit, as shown in the follow-
ing diagram.

Note: Connect dynamic brake resistors with the following resistance speci-

fications.
400-V SERVOPACKs: Higher than 0.8

Use the following dynamic brake contactor and Surge Absorption Unit. The main circuit
Surge Absorption Unit is available as a side-connection type or a front-connection type.

Name

Model

Manufacturer

Contactor

SC-4-1/G 24-VDC
coil

Fuji Electric Co., Ltd.

Main Circuit
Surge Absorption
Unit

Front Connection

SZ-ZM1

Side Connection

SZ-ZM2

Coil Surge Absorption Unit

SZ-Z4

DV

DU

DW

SGDH SERVOPACK

Dynamic brake
resistors

DB0N

DB24

Dynamic brake
contactor

Main circuit
Surge Absorption Unit

Coil surge
absorption unit