Appendix A List of Parameters
A-2
A.1 Parameters
The following list shows parameters and their settings.
Table A.1 List of Parameters
Category
Parameter
No.
Name
Unit
Setting
Range
Factory
Setting
Reference
Function
Selection
Constants
Pn000
Function Selection Basic Switches
∗3
-
-
0000
4.1.1, 4.3.5
Pn001
Function Selection Application Switches
1
∗3
-
-
0000
4.1.2, 4.4.2,
4.5.7
Pn002
Function Selection Application Switches
2
∗3
-
-
0000
4.2.8,
4.2.10,
4.7.2
Pn003
Function Selection Application Switches
3
-
-
0002
5.5
Pn004
Fixed Parameters (Do not change.)
-
-
0000
-
Pn005
-
-
0000
-
Gain Related
Constants
Pn100
Speed Loop Gain
Hz
1 to 2000
40
5.2.1
Pn101
Speed Loop Integral Time Constant
0.01 ms
15 to 51200
2000
5.2.1
Pn102
Position Loop Gain
1/s
1 to 2000
40
5.2.1
Pn103
Inertia Ratio
%
0 to 10000
0
5.2.1, 5.3.3
Pn104
2nd Speed Loop Gain
Hz
1 to 2000
40
-
Pn105
2nd Speed Loop Integral Time Constant
0.01 ms
15 to 51200
2000
-
Pn106
2nd Position Loop Gain
1/s
1 to 2000
40
-
Pn107
Bias
min
-1
0 to 450
0
5.2.4
Pn108
Bias Addition Width
reference
units
0 to 250
7
5.2.4
Pn109
Feed-forward
%
0 to 100
0
5.2.2
Pn10A
Feed-forward Filter Time Constant
0.01 ms
0 to 6400
0
4.2.5
Pn10B
Gain-related Application Switches
∗3
-
-
0000
5.2.5
Pn10C
Mode Switch Torque Reference
%
0 to 800
200
5.2.5
Pn10D
Mode Switch Speed Reference
min
-1
0 to 10000
0
5.2.5
Pn10E
Mode Switch Acceleration
10 min
-1
/s
0 to 3000
0
5.2.5
Pn10F
Mode Switch Error Pulse
reference
units
0 to 10000
0
5.2.5
Pn110
Online Autotuning Switches
∗3
-
-
0010
5.3.4
Pn111
Speed Feedback Compensation
∗2
%
1 to 500
100
5.2.6
Pn112
Fixed Parameters (Do not change.)
%
0 to 1000
100
-
Pn113
-
0 to 1000
1000
-
Pn114
-
0 to 1000
200
-
Pn115
-
0 to 65535
32
-
Pn116
-
0 to 65535
16
-
Pn117
%
20 to 100
100
-
Pn118
%
50 to 100
100
-