2 applied operation – Yaskawa Large Capacity Sigma II Series User Manual
Page 240

6 Using the Digital Operator
6-20
6.2 Applied Operation
This section describes how to apply the basic operations using the Digital Operator to run and
adjust the motor. Read the basic operations described in 6.1 Basic Operation before proceeding
to this section.
Parameters for applied operation can be set in the auxiliary function mode. The following table
shows the parameters in the auxiliary function mode.
Note: These parameters and those indicated as Pn are displayed as
shown below if their passwords are set (Fn010). These parameters
cannot be changed.
Parameter
No.
Function
Remarks
Fn000
Alarm traceback data display
Fn001
Rigidity setting during online autotuning
(See note.)
Fn002
JOG mode operation
Fn003
Zero-point search mode
Fn004
(Reserved constant)
Fn005
Parameter settings initialization
(See note.)
Fn006
Alarm traceback data clear
(See note.)
Fn007
Writing inertia ratio data obtained from online autotuning to EEPROM (See note.)
Fn008
Absolute encoder multiturn reset and encoder alarm reset
(See note.)
Fn009
Automatic tuning of analog (speed, torque) reference offset
(See note.)
Fn00A
Manual adjustment of speed reference offset
(See note.)
Fn00B
Manual adjustment of torque reference offset
(See note.)
Fn00C
Manual zero-adjustment of analog monitor output
(See note.)
Fn00D
Manual gain-adjustment of analog monitor output
(See note.)
Fn00E
Automatic offset-adjustment of motor current detection signal
(See note.)
Fn00F
Manual offset-adjustment of motor current detection signal
(See note.)
Fn010
Password setting (protects from parameter changes)
Fn011
Motor models display
Fn012
SERVOPACK software version display
Fn013
Multiturn limit value setting change when a Multiturn Limit Disagree-
ment alarm occurs
(See note.)
Fn014
Clear of option unit detection results
Flashing for one second