6 Using the Digital Operator

6.2.10 Manual Zero Adjustment and Gain Adjustment of Analog Monitor Output

6-44

6.2.10 Manual Zero Adjustment and Gain Adjustment of Analog Monitor

Output

Motor speed, torque reference, and position error can be monitored through the analog mon-
itor output. Refer to 5.5 Analog Monitor.

Use the manual zero adjustment function to compensate for the output voltage drift or the
zero point drift caused by noise entering the monitor system. The gain adjustment function
can be changed to match the sensitivity of the measuring system.

The output voltage of the analog monitor is ±8 V max. The output voltage will be reversed if ±8 V is
exceeded.

Monitor output voltage

Zero adjustment

Gain adjustment

Zero Setting Range:

± 2V

→ 17 mV/LSB

Gain Setting Range: 50 to 150%

→ 0.4 %/LSB

Setting Unit

INFO