7 Servo Selection and Data Sheets

7.3.3 Overload Characteristics

7-18

7.3.3 Overload Characteristics

SERVOPACKs have a built-in overload protective function that protects the SERVOPACKs
and servomotors from overload. Allowable power for the SERVOPACKs is limited by the
overload protective function as shown in the figure below.

The overload detection level is set under hot start

1

conditions at a servomotor ambient tem-

perature of 40

°C (104 °F).

Fig. 7.1 Overload Characteristics

1

Hot Start

A hot start indicates that both the SERVOPACK and the servomotor have run long enough at the rated
load to be thermally saturated.

TERMS

Operating Time (s)

Motor Current

Rated Current

Maximum Current

Approx.

Rated current + Maximum current

2

10000

1000

100

5

1

10000

1000

100

5

1

10000

1000

100

10

5

1

10000

1000

100

10

5

1